CVE-2024-43653

Severity: Important
Published: 2024-01-01

Fix Status by Distribution

Fixed in 0 of 27 tracked Linux releases

Fix evidence last checked: 2026-07-24 08:45 UTC

Get alerted when your releases are fixed
No fix evidence found:
AlmaLinux 10
AlmaLinux 8
AlmaLinux 9
Debian 11 (Bullseye)
Debian 12 (Bookworm)
Debian 13 (Trixie)
Oracle Linux 10
Oracle Linux 8
Oracle Linux 9
Red Hat Enterprise Linux 10
Red Hat Enterprise Linux 7 (Extended Lifecycle Support)
Red Hat Enterprise Linux 8
Red Hat Enterprise Linux 9
Rocky Linux 10
Rocky Linux 8
Rocky Linux 9
SUSE Linux Enterprise Server 12 SP5
SUSE Linux Enterprise Server 15 SP5
SUSE Linux Enterprise Server 15 SP6
SUSE Linux Enterprise Server 15 SP7
SUSE Linux Enterprise Server 16
Ubuntu 22.04 LTS (Jammy Jellyfish)
Ubuntu 24.04 LTS (Noble Numbat)
Ubuntu 25.04 (Plucky Puffin)
Ubuntu 25.10 (Questing Quokka)
Ubuntu 26.04 LTS (Resolute Raccoon)
Ubuntu 26.10 (Stonking Stingray)
Interested in being alerted when these distributions have fixes? Set up an alert.

Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Exploit evidence

No public exploit evidence reported by NVD

Last checked: 2026-07-31 19:09 UTC

  • No exploitation evidence · CISA Coordinator (Assessed 2025-01-09 14:39 UTC)

NVD evidence for CVE-2024-43653 is reported, not independently verified by Package Alert. It does not establish exploit reliability or applicability to a particular package or environment.