CVE-2024-43659

Severity: Important
Published: 2024-01-01

Fix Status by Distribution

Fixed in 0 of 27 tracked Linux releases

Fix evidence last checked: 2026-07-24 08:45 UTC

Get alerted when your releases are fixed
No fix evidence found:
AlmaLinux 10
AlmaLinux 8
AlmaLinux 9
Debian 11 (Bullseye)
Debian 12 (Bookworm)
Debian 13 (Trixie)
Oracle Linux 10
Oracle Linux 8
Oracle Linux 9
Red Hat Enterprise Linux 10
Red Hat Enterprise Linux 7 (Extended Lifecycle Support)
Red Hat Enterprise Linux 8
Red Hat Enterprise Linux 9
Rocky Linux 10
Rocky Linux 8
Rocky Linux 9
SUSE Linux Enterprise Server 12 SP5
SUSE Linux Enterprise Server 15 SP5
SUSE Linux Enterprise Server 15 SP6
SUSE Linux Enterprise Server 15 SP7
SUSE Linux Enterprise Server 16
Ubuntu 22.04 LTS (Jammy Jellyfish)
Ubuntu 24.04 LTS (Noble Numbat)
Ubuntu 25.04 (Plucky Puffin)
Ubuntu 25.10 (Questing Quokka)
Ubuntu 26.04 LTS (Resolute Raccoon)
Ubuntu 26.10 (Stonking Stingray)
Interested in being alerted when these distributions have fixes? Set up an alert.

After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).

Exploit evidence

No public exploit evidence reported by NVD

Last checked: 2026-07-31 19:09 UTC

  • No exploitation evidence · CISA Coordinator (Assessed 2025-01-09 14:48 UTC)

NVD evidence for CVE-2024-43659 is reported, not independently verified by Package Alert. It does not establish exploit reliability or applicability to a particular package or environment.