CVE-2024-43660

Severity: Important
Published: 2024-01-01

Fix Status by Distribution

Fixed in 0 of 27 tracked Linux releases

Fix evidence last checked: 2026-07-24 08:45 UTC

Get alerted when your releases are fixed
No fix evidence found:
AlmaLinux 10
AlmaLinux 8
AlmaLinux 9
Debian 11 (Bullseye)
Debian 12 (Bookworm)
Debian 13 (Trixie)
Oracle Linux 10
Oracle Linux 8
Oracle Linux 9
Red Hat Enterprise Linux 10
Red Hat Enterprise Linux 7 (Extended Lifecycle Support)
Red Hat Enterprise Linux 8
Red Hat Enterprise Linux 9
Rocky Linux 10
Rocky Linux 8
Rocky Linux 9
SUSE Linux Enterprise Server 12 SP5
SUSE Linux Enterprise Server 15 SP5
SUSE Linux Enterprise Server 15 SP6
SUSE Linux Enterprise Server 15 SP7
SUSE Linux Enterprise Server 16
Ubuntu 22.04 LTS (Jammy Jellyfish)
Ubuntu 24.04 LTS (Noble Numbat)
Ubuntu 25.04 (Plucky Puffin)
Ubuntu 25.10 (Questing Quokka)
Ubuntu 26.04 LTS (Resolute Raccoon)
Ubuntu 26.10 (Stonking Stingray)
Interested in being alerted when these distributions have fixes? Set up an alert.

The CGI script <redacted>.sh can be used to download any file on the filesystem. This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High, but credentials required. Impact: Critical – The script can be used to download any file on the filesystem, including sensitive files such as /etc/shadow, the CGI script source code or binaries and configuration files. CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/S:P/AU:Y CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The confidentiality of all files of the devicd can be compromised (VC:H/VI:N/VA:N). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, this attack in isolation does not have a safety impact. The attack can be automated (AU:Y).

Exploit evidence

No public exploit evidence reported by NVD

Last checked: 2026-07-31 19:09 UTC

  • No exploitation evidence · CISA Coordinator (Assessed 2025-01-09 14:37 UTC)

NVD evidence for CVE-2024-43660 is reported, not independently verified by Package Alert. It does not establish exploit reliability or applicability to a particular package or environment.