CVE-2026-50031
Fix Status by Distribution
Fixed in 21 of 27 tracked Linux releases
Fix evidence last checked: 2026-11-27 21:02 UTC
Get alerted when your releases are fixedFixed in:
AlmaLinux 10
ALSA-2026:36211 · Published: 2026-07-13
AlmaLinux 8
ALSA-2026:36307 · Published: 2026-07-08
AlmaLinux 9
ALSA-2026:36210 · Published: 2026-07-08
Oracle Linux 10
ELSA-2026-36211 · Published: 2026-07-16
Oracle Linux 8
ELSA-2026-36307 · Published: 2026-07-07
Oracle Linux 9
ELSA-2026-36210 · Published: 2026-07-07
Red Hat Enterprise Linux 10
RHSA-2026:36211 · Published: 2026-07-07
Red Hat Enterprise Linux 7 (Extended Lifecycle Support)
RHSA-2026:48826 · Published: 2026-07-30
Red Hat Enterprise Linux 8
RHSA-2026:36307 · Published: 2026-07-07
Red Hat Enterprise Linux 9
RHSA-2026:36210 · Published: 2026-07-07
Rocky Linux 10
RLSA-2026:36211 · Published: 2026-07-13
Rocky Linux 8
RLSA-2026:36307 · Published: 2026-07-08
Rocky Linux 9
RLSA-2026:36210 · Published: 2026-07-13
SUSE Linux Enterprise Server 12 SP5
SUSE-SU-2026:2679 · Published: 2026-06-29
SUSE Linux Enterprise Server 15 SP5
SUSE-SU-2026:4277 · Published: 2026-09-22
SUSE Linux Enterprise Server 15 SP6
SUSE-SU-2026:4277 · Published: 2026-09-22
SUSE Linux Enterprise Server 15 SP7
SUSE-SU-2026:4277 · Published: 2026-09-22
SUSE Linux Enterprise Server 16
SUSE-SU-2026:22163 · Published: 2026-06-18
Ubuntu 22.04 LTS (Jammy Jellyfish)
USN-8613-1 · Published: 2026-07-27
Ubuntu 24.04 LTS (Noble Numbat)
USN-8613-1 · Published: 2026-07-27
Ubuntu 26.04 LTS (Resolute Raccoon)
USN-8613-1 · Published: 2026-07-27
No fix evidence found:
ipmi-oem in FreeIPMI before 1.6.18 has exploitable buffer overflows on response messages. The Intelligent Platform Management Interface (IPMI) specification defines a set of interfaces for platform management. It is implemented by a large number of hardware manufacturers to support system management. It is most commonly used for sensor reading (e.g., CPU temperatures through the ipmi-sensors command within FreeIPMI) and remote power control (the ipmipower command). The ipmi-oem client command implements a set of a IPMI OEM commands for specific hardware vendors. If a user has supported hardware, they may wish to use the ipmi-oem command to send a request to a server to retrieve specific information. Two subcommands "ipmi-oem dell get-active-directory-config" and "ipmi-oem fujitsu get-sel-entry-long-text" were found to have exploitable buffer overflows on response messages.
Exploit evidence
Last checked: 2026-07-31 19:17 UTC
No exploitation evidence · CISA Coordinator (Assessed 2026-06-03 13:38 UTC)